a specialised provider of a complete selection of chains, sprockets, gears, equipment racks, V-belts, couplings and reducers. Keeping in mind that excellent service is the key to cooperating with clientele, we strive to fulfill higher quality standards, offer you competitive charges and make certain prompt supply. The product well displays environmental protection and vitality saving. Expert EPTT EPT EPTT saving air cooler
We are a expert warmth exchanger, condenser, evaporator, heat pump,air cooler and air conditioner manufacturer in EPTT,which has more than fifteen a long time expertise in HVAC area. Our goods have been exported to Europe,United states, Japan and Center EPT etc.
EPT Characteristics
1. Condensers are the first option of refrigeraion and AC sector. Condenser with a ability 8kW~1800kW and area twenty~4100 sq. meter which has broad application range. It is fleXiHu (West EPT) Dis.ble to match which diverse dimension of compressor. Use reduced specific energy intake supporters, high effectiveness interior groove copper tube and sine wave EPT fin. EPTTble substance with slim but rigid enclosure tough gloss powEPTTcoated sheet metallic delivers corrosion proof unEPTThostile setting. There are top air outlet or aspect air outlet build for C1 sequence, quotV quot type for C2 collection. C2 float coil can prevent refrigerant leakage effictively, it assures a sturdy and basic safety finned warmth exchanger.
two. EPT effectiveness warmth exchanger: potential types for maXiHu (West EPT) Dis.mizing the heat transfer relative to the vitality usage of the enthusiast. EPT and tube coupling layout for low force fall in the coil on the media sides(maXiHu (West EPT) Dis.mum 100KPa at water designing problem). Our thermodynamic and aerodynamic developing computer software is EPTT yr tested and proved in Germany
3. Enthusiast: only choose lower particular power consumption enthusiasts. Supporter nozzle designs for maXiHu (West EPT) Dis.mum air flow and air throw.Our enthusiasts from the world`s foremost manufacturer are practically proved to be reputable in operation and EPTT lasting. EPT: protection course IP 54 and insulation course F. Air separator for each and every enthusiast.
four. We faXiHu (West EPT) Dis.Hu (West EPT) Dis.tate you to have a EPTT lasting and minimal maintainance operation. EPTTble content and rigid enclosure with challenging gloss powEPTTcoated complete. Protecting enclosure for equally manifolds and U-bends. Device design for outdoor installation. one hundred% leakage tested at 31bar.
Choices
1. Coil style refrigerant: R414A, R407C
two. Numerous circuits.
3. Sub-cooling circuits.
four. Stainless steel or EPT casing.
five. Coated EPT, copper fins and anti-corrosion expoxy fin.
six. Explosion ploof motor.
7. EPTT fin spacing.
Situation
Air inlet temp. twenty five ordmC condensing temp. 40 ordmC refrigerant inlot temp. sixty five ordmC liquid sub-cooling 3K relative humidity 40% environment force one bar(sea level)
EPTnical parameter
Air cooled condenser C2 collection parameter(fin room two.1mm)
Paramaters:
SHSL-D1 sequence (fin area two.1mm)
Variety |
SHSL-D1-005-1×350 |
SHSL-D1-006-1×350 |
SHSL-D1-007-1×350 |
SHSL-D1-009-1×450 |
SHSL-D1-011-1×450 |
SHSL-D1-013-1×450 |
SHSL-D1-014-1×500 |
SHSL-D1-017-1×500 |
SHSL-D1-571-1×500 |
||||||
Capacity |
JCEP |
35 ordmC outdoor temp. |
Inlet |
forty five ordmC, |
KW |
4.89 |
five.ninety |
six.eighty three |
9.39 |
ten.ninety nine |
thirteen.33 |
14.32 |
17.01 |
19.80 |
|
outlet |
40 ordmC |
Y |
|||||||||||||
twenty% Glycol |
Inlet |
forty five ordmC |
four.72 |
5.69 |
6.69 |
8.ninety |
10.sixty one |
13.05 |
13.ninety one |
16.eleven |
19.29 |
||||
outlet |
forty ordmC |
Y |
|||||||||||||
Medium |
JCEP circulation |
M3/h |
.85 |
1.03 |
1.twenty |
1.sixty three |
1.ninety one |
2.thirty |
2.fifty |
3.00 |
3.fifty |
||||
Stress drop |
kPa |
36.00 |
31.00 |
58.00 |
twenty five.00 |
forty |
80 |
50 |
60 |
40 |
|||||
Air movement |
M3/h |
2828 |
2712 |
2492 |
6199 |
5827 |
5225 |
8469 |
8168 |
7601 |
|||||
Y |
|||||||||||||||
Admirer motor |
Stage |
one |
one |
one |
three |
three |
3 |
3 |
3 |
three |
|||||
W |
a hundred and forty |
140 |
one hundred forty |
540 |
540 |
540 |
830 |
830 |
830 |
||||||
Y |
|||||||||||||||
A |
.sixty |
.60 |
.60 |
one.ten |
one.10 |
one.10 |
1.forty five |
1.45 |
one.forty five |
||||||
Y |
|||||||||||||||
Fan |
No X phi |
1x1x350 |
1x1x350 |
1x1x350 |
1x1x450 |
1x1x450 |
1x1x450 |
1x1x500 |
1x1x500 |
1x1x500 |
|||||
Audio strain level |
dB(A) |
31 |
31 |
31 |
43 |
43 |
43 |
forty nine |
forty nine |
49 |
|||||
Y |
10m |
Application
EPTT discipline: method engineering, heat / EPTT EPTT, EPTT era, chemical business, air conditioning chiller, warmth transformer, smelting, and so on.. It is suited for all tools which needs warmth dissipation and is set up in the open air.